FOCAS-1500c

15ppm bilge alarm focas 1500c


Description    

  • FOCAS-1500c Bilge Alarm serves to continuously measure the concentration of oil in the bilge and other waste water produced on a ship.
  • FOCAS-1500c meets the requirement of IMO Resolution MEPC60 (33) and has type-approval from JG, and DOT.

Features

  • It measures only the oil concentration, free from affection of detergent and suspended solid matter in the water.
  • The production of air bubbles is inhibited to permit stabilized measurement. 
  • Dual alarm system.   An oil content alarm is given when the oil concentration exceeds 15ppm and a set alarm is given in the event of input (sample water) or instrument failure.
  • "CHECK" button giving simple operation test.
  • Installation and connection are carried out with ease because it is samll and right.

 PRODUCT DETAIL: 

Standard Specifications

Measuring Method: Turbidity by ultrasonic waves.

Measuring Cycle: about 17 sec. 

Measuring Range: 0~30ppm.

Measuring Accuracy: Within ±5ppm (at 15ppm).

Measuring Pressure: 0.2~3.0bar (about 0.02~0.3MPa).

Measuring Water Temperature: 2~45℃.

Alarm Setting: 15ppm.

Ambient Temperature: 0~55℃.

Allowable Humidity: max. 90%.

Variation Test: ±0.7G.

Angle of Inclination: 22.5° from horizontal plane.

Sample Water Flow Rate: 0.0002~0.003m3/min. (0.2~3 lit/min.).

Power Supply Voltage: AC100, 110, 115, 220V ・ 50/60Hz.

Power Consumption: 40W average (150VA max.).

Weight: Approx. 7.5Kg.

Outside Dimension: 255W×290H×158D 〔m/m〕.

Read 608 times
More in this category: OMD-2005 »