OMD-2005

omd 2005

SPECIFICATION

Range: 0 - 30 ppm, Trend up to 50 ppm

Accuracy: According IMO MEPC. 107(49)

Linearity: Up to 30 ppm better than +/- 2%

Display: Green Graphic Display

Power Supply: 24 V - 240 V AC or DC Automatic Voltage Selection

Consumption: < 15 VA

 

 

 

 PRODUCT DETAIL: 

Alarm Points 1 + 2: Adjustable between 1 - 15 ppm (Works adjustment 15 ppm)

Alarm 1 Operating Delay (for annunciator purpose): Adjustable between 1 - 540 ppm (Works adjustment 2 sec)

Alarm 2 Operating Delay (for control purposes): Adjustable between 1 - 10 ppm (Works adjustment 10 sec)

System Fault Alarm: Red LED

Alarm Contact Rating: Potential free 1-pole change over contacts, 3 A / 240 V

Alarm Indication: Red LED's

Output Signal: 0 - 20 mA or 4 - 20 mA, reversible ext. Load < 150 Ohm

Sample Water Pressure: 0,1 - 10 bar

Sample Flow: Approx. 0,1 - 4 l/min, depending to pressure

Ambient Temperature: + 1 to +55o C

Sample Water Temperature: + 1 to +65o C

Roll: Up to 45o C

Size (over all): 360 mm W X 240 mm H X 100 mm D

Degree of Protection: IP 65

Weight: 7,3 Kgs

Pipe Connections: R 1/4 " Female

According to regulations of IMO Resolution MEPC. 107(49) U.S. Coast Guard approved

 